Digital Output Capture IP

Digital Output Capture IP is an algorithm IP that captures a signal output from a measurement target as 0/1 data. It judges pass/fail of the captured data. It also saves the captured data to a file.

This IP is used for the following measurements.

  • Reading chip ID/device ID
  • Evaluation/Verification of digital code form Sensor ICs/Linear ICs/Analog ICs
  • Trimming for Sensor ICs/Linear ICs/Analog ICs
  • Redundancy for memory devices

Revision contents on Rev 2.03.00

Features

Digital Output Capture IP has the following functions.

Revisions

Released atNumberDescription
February 13, 20182.03.00
October 30, 20172.02.00
  • Fixed an issue that the device outputs could not be captured correctly when [Capture Mode] was [Address Selection].
  • Added [Cycle Selection] to [Capture Mode].
  • Added a function which customizes save file name.
December 06, 20162.01.00
  • Support “power-off control” function on “Flow Item List Area” in Expert Mode.
  • Support External Power Supply Control Plugin R1.01.00.
May 13, 20162.00.00
  • Change the product name.
    • New product name : Digital Output Capture IP
    • Old product name : Pattern Capture IP
    • If you have already a contract with the old product names, the change procedures of the contract associated with the product name change is not required.
  • Change the IP name.
    • New IP name : Digital Output Capture IP
    • Old IP name : PatternCapture_IP
    • The project that was created in the old IP name is also able to use as it is..
  • Add the AWG Condition tab.
    • The AWG Condition tab is enabled by Arbitrary Waveform Applying Plugin.
    • Arbitrary Waveform Applying Plugin adds the function of applying arbitrary waveform synchronized with pattern to measurement object to algorithm IPs.
    • Please refer to Product Page for details.
  • Add the External Power Supply tab.
    • The External Power Supply tab is enabled by External Power Supply Control Plugin.
    • External Power Supply Plugin adds the function of applying a voltage from external power supply controlled by GPIB.
    • Please refer to Product Page for details.
  • Add the Document tab.
    • The Document tab has the buttons for displaying the reference manual and revision history.
  • Change the tab name.
    • Before: Measurement Condition
    • After: Measurement Result
  • Change the name of parameters and its place.
Name of parameter Place
Before After Before After
"Save Measured Data" "Save measured data" Capture Condition tab Measurement Result tab
"Save captured data"(No name change) Capture Condition tab Measurement Result tab
"CSV Save Folder" "Folder" Capture Condition tab Measurement Result tab
"Capture Pin"(No name change) Measurement Result tab Capture Condition tab
"Output Form"(No name change) Measurement Result tab Capture Condition tab
"Serial Bit Width"(No name change) Measurement Result tab Capture Condition tab

The project that was created in the old IP name is also able to use as it is..

July 03, 20151.02.00
  • Add function of setting variable for “Upper Limit” and “Lower Limit”.
  • Add Judgement of total PASS count.
  • Add function of saving “individual judgement result”, “individual measurement data”, “total judgement result”, “total pass count” to the user variables by interpose processing.

The following error message will appear in console when a project that is made by previous revision is loaded at first time.

Error occurred.
Error Code: 001-0130-013
[Measurement Condition]
The following variable error occured.
dummy:
Variable not defined: "dummy".

This error is caused by revision-up. There is no problem at the function of this IP. The message does not appear in console when a project that is made by new revision.

February 02, 20151.01.00

Support IP Manager

January 26, 20151.00.00

First edition